Trans Tek Series 350 LVDTs

 
Specifications
 
FOR DC-DC OPERATION
Model 0350-0000 0351-0000
Working Range, ± in (mm) 0.050 (1.27) 0.10 (2.54)
Mechanical Travel, in (mm) 0.16 (4.06) 0.31 (7.87)
Input, VDC 6 min to 28 max
Nominal F.S. Output +- VDC (tested with load impedance simulating open circuit)
@ 6 Volt Input 1.2 2.1
@ 15 Volt Input 3.0 5.4
@ 24 Volt Input 5.0 9.0
@ 28 Volt Input 5.6 10.1
Input Current 6.3 mA @ 6 volt input to 48 mA @ 28 volt input
Linearity % Full Scale Total Working Range ± 0.50

Internal Carrier Frequency, Hz

13000 12000
Nominal Greater Than:  
% Ripple, RMS (Nominal) 0.7 0.7
Output Impedance, Ohms 2500 3500
Temperature Range -54°C - 93°C (-65°F - 200°F)
Resolution Infinite
Total Length A, in (mm) 3.01 (76.5) 3.52 (89.4)
Shaft Extension B, in (mm) 0.41 (10.4) 0.56 (14.2)
Tie Force Max, grams 57 170
Weight, grams 200 207
 