20 kip Capacity Load Cells

 
The load cells mentioned below are designed for 20 kip loading capacity. The designation number on each load cell is defined as follows: LC (load cell) - A (aluminum) - # (capacity, kip) - # (consecutive no.) - # (cross section area, in2) - # (inner diameter, in) - # (length, in).
 

Designation Number

Outer Diameter (in)

Excitation Voltage (V)

Resistance for Balance Resistor (kΩ, between B and D)

Calibration Equation: Calibration Data (VDC)
Uout= UcalA UcalB
LC-A-20-1-0.687-0.625-3.37 1.125 6.00 80 .49778F-.00768 0.90 -0.89
LC-A-20-2-0.687-0.625-3.37 1.125 6.00 60 .50017F-.00815 0.89 -0.91
LC-A-20-3-0.687-0.625-3.37 1.125 4.00 - .51602F-.01587 0.90 -0.91
LC-A-20-4-0.687-0.625-3.37 1.125 4.00 50 .49982F-.00905 0.90 -0.90
LC-A-20-5-0.687-0.625-3.37 1.125 4.00 - .50000F-.01451 0.89 -0.91
LC-A-20-6-0.687-0.625-3.37 1.125 4.00 30 .49995F-.01676 0.88 -0.90
LC-A-20-7-0.687-0.625-3.37 1.125 4.00 - .50027F-.00815 0.89 -0.91
LC-A-20-8-0.687-0.625-3.37 1.125 4.00 50 .49965F-.00816 0.90 -0.90
LC-A-20-9-0.687-0.625-3.37 1.125 4.00 - .50027F-.00815 0.90 -0.90
LC-A-20-10-0.687-0.625-3.37 1.125 4.00 - .50032F-.00951 0.89 -0.91
LC-A-20-11-0.687-0.625-3.37 1.125 4.00 - .49987F-.00951 0.90 -0.90
LC-A-20-12-0.687-0.625-3.37 1.125 4.00 - .50000F-.01269 0.90 -0.90
LC-A-20-13-0.687-0.625-3.37 1.125 4.00 - .49960F-.01041 0.88 -0.90
LC-A-20-14-0.687-0.625-3.37 1.125 4.00 60 .50015F-.01314 0.89 -0.91
LC-A-20-15-0.687-0.625-3.37 1.125 4.00 - .49977F-.01132 0.89 -0.90
LC-A-20-16-0.687-0.625-3.37 1.125 4.00 40 .50027F-.00815 0.91 -0.91
LC-A-20-17-0.687-0.625-3.37 1.125 4.00 50 .50040F-.00769 0.90 -0.90